Door Interlock - Euchner - Head - Replacement

Applies to machines built from: 
June, 2011
AD0226 Rev D

Door Interlock - Euchner - Service

This procedure tells you how to replace the head on the door-interlock switch. This new head is a quick and easy replacement of the polycarbonate component, and will restore the interlock to full functionality. Over time, or after excessive force, the polycarbonate components inside the interlock can wear out. Do this procedure if the door interlock system has one of these symptoms:
  1. The door does not lock.
  2. The machine shows door fault alarms.
  3. The CE Interlock Switch Key (P/N 61-1013/61-1015/61-1016) does not go smoothly into the interlock head.
Safety Notes
Caution: When you do maintenance or repair on CNC machines and their components, you must always follow basic safety precautions. This decreases the risk of injury and mechanical damage.

Do these steps before you do work in the machine or in the control cabinet:
  • Set the main circuit breaker to the OFF position.
  • Use an approved lock with an approved safety tag. Always follow lock-out procedures in accordance to local government rules.
  • After turning off the machine, wait at least 5 minutes before working in the control cabinet, to allow power to dissipate. Wait for the voltage indicator LED on the vector drive to go off completely.
  • Always turn off the main air supply when you work on any part of the pneumatic system.
  • Make sure to rest the spindle head on a block of wood when work is done on a vertical axis. This will prevent any unintended movement that could result in the axis falling.
  • Never alter any safety circuits on the machine.
You should not do machine repair or service procedures unless you are qualified and knowledgeable about the processes. Serious damage to the machine components can result in costly repairs. The service technicians at your Haas Factory Outlet (HFO) have the training and experience, and are certified to do these tasks safely and correctly. The repair and service work performed by your HFO is protected with a limited warranty.
danger: Some service procedures can be dangerous or life-threatening. DO NOT attempt a procedure that you do not fully understand. If you have any doubts about doing a procedure contact your Haas Factory Outlet (HFO) and schedule a service visit.

Machine Compatibility

Do this procedure for:

  • Machines that have a TP-series Euchner door-interlock system with a part number [1] that ends with a K, N, or M.

 

Parts Included

[A]
93-2309
QTY: 1
DOOR INTERLOCK, HEAD REPLACEMENT EUCHER

Tools Required

T10 Torx bit

Step 1

Push POWER OFF.

Set the main circuit breaker to the OFF position.

Lock the main circuit breaker. Use an approved lock with an approved safety tag.

Step 2

Remove the old interlock head [1] from the actuator body.

Install the new interlock HEAD [A].

Use a Torx driver to tighten the (4) screws [2]. Do not tighten the screws too much.

Test the interlock:

  • Close the doors.
  • Run the spindle at more than 1000 rpm.
  • The doors lock.

Be aware: Many service and repair procedures should be done only by authorized personnel. The service technicians at your Haas Factory Outlet (HFO) have the training, experience, and are certified to do these tasks safely and correctly. You should not do machine repair or service procedures unless you are qualified and knowledgeable about the processes.

Danger: Some service procedures can be dangerous or life-threatening. DO NOT attempt a procedure that you do not completely understand. Contact your Haas Factory Outlet (HFO) and schedule a service technician visit if you have any doubts about doing a procedure.