Macro statements select and turn on and off the probe the same as M-codes.

Probe Macro Values

M-Code System Variable Macro Value Probe
M59 P2 ; #12002 1.000000 Tool Probe Selected
M69 P2 ; #12002 0.000000 Work Probe Selected
M59 P3 ; #12003 1.000000 Probe Enable
M69 P3 ; #12003 0.000000 Probe Disable

If you assign the system variable to a viewable global variable, you can see the macro value change in the Macro Vars tab under CURRENT COMMANDS.

For example,

M59 P3 ; #10003=#12003 ;

The global variable #10003 shows the output from M59 P3 ; as 1.000000. This means that either the tool probe or work probe is on.

Be aware: Many service and repair procedures should be done only by authorized personnel. The service technicians at your Haas Factory Outlet (HFO) have the training, experience, and are certified to do these tasks safely and correctly. You should not do machine repair or service procedures unless you are qualified and knowledgeable about the processes.

Danger: Some service procedures can be dangerous or life-threatening. DO NOT attempt a procedure that you do not completely understand. Contact your Haas Factory Outlet (HFO) and schedule a service technician visit if you have any doubts about doing a procedure.