Check Tool Probe

Next Generation Control Mill Operator's Manual

The Online Interactive Operator's Manual is currently available in English only.

A PDF version of the Operator's Manual is available for download in multiple languages. Click the link below to view the Operator's Manual in your language. Click "Continue" to view the online version in English.

Get a translated PDF Download Continue

Do these steps to make sure the tool probe operates correctly:

Tool Probe Test

  1. In MDI mode, run:

     

    M59 P2 ;
    G04 P1.0 ;
    M59 P3 ;

     

    This turns on tool probe communication, delays one second, and turns on the tool probe. The LED [1] on the tool probe flashes green.

  2. Touch the stylus [2].

    The machine makes a "beep" sound and the LED becomes red [1]. This tells you that the tool probe is started.

  3. Press RESET to deactivate the probe.

    The probe LED [1] turns off.

Be aware: Many service and repair procedures should be done only by authorized personnel. The service technicians at your Haas Factory Outlet (HFO) have the training, experience, and are certified to do these tasks safely and correctly. You should not do machine repair or service procedures unless you are qualified and knowledgeable about the processes.

Danger: Some service procedures can be dangerous or life-threatening. DO NOT attempt a procedure that you do not completely understand. Contact your Haas Factory Outlet (HFO) and schedule a service technician visit if you have any doubts about doing a procedure.

Feedback